Cannon-Fenske Routine Viscometers

Calibrated CFRC Series

For measuring kinematic viscosity of transparent Newtonian liquids particularly petroleum products. Or lubricants, according to ASTM D 445 and ISO 3105.

Provided with certificate of calibration and instruction sheet.

Minimum sample of volume 7ml. Requires Liquid bath depth of 203mm (8 inches).

Categories: , .

Product Description

Cannon-Fenske

Cannon-Fenske Routine Viscometers

Cannonfenske UBC Series

Calibrated CFRC Series

For measuring kinematic viscosity of transparent Newtonian liquids particularly petroleum products. Or lubricants, according to ASTM D 445 and ISO 3105.

Provided with certificate of calibration and instruction sheet.

Minimum sample of volume 7ml. Requires Liquid bath depth of 203mm (8 inches).

Holder for above as follows:

Molded Plastic Holder (Model H100) Part No: 9726-M50

Neoprene Rubber Holder (Model H110) Part No: 9726-M53

Size Calibrated CFRC Series Approx Constant CSt/s Range Centistrokes
25 9721-B50 0.002 0.5 to 2
50 9721-B53 0.004 0.8 to 4
75 9721-B56 0.008 1.6 to 8
100 9721-B59 0.015 3 to 15
150 9721-B62 0.035 7 to 35
200 9721-B65 0.1 20 to 100
300 9721-B68 0.25 50 to 250
350 9721-B71 0.5 100 to 500
400 9721-B74 1.2 240 to 1200
450 9721-B77 2.5 500 to 2500
500 9721-B80 8 1600 to 8000
600 9721-B83 20 4000 to 20000
650 9721-B86 45 9000 to 45000
700 9721-B89 100 20000 to 100000

Calibration Standards for Routine Viscometers can be found here.

Cannon Ubbelohde Viscometers

Cannonfenske CUC Series

Calibrated CUC Series

Suspended level viscometer for measurement of Kinematic viscosity of transparent Newtonian liquids to ASTM D445 and ISO 3104. Also used for evaluating jet and hydraulic lubricants requires no kinetic energy corrections over 0.5 to 100000 centistrokes range. Viscometer constant is the same at all temperatures. Specifications conform to ASTM D 446 and ISO 3105.

Provided with certificate of calibration and instruction sheet.

Minimum sample volume 11ml. Require liquid bath depth of 254mm (10 Inches) must be submerged to approximately 220mm (8.5 inches).

Holder for above as follows:

Molded Plastic Holder (Model H101), Part No: 9726-M70

Neoprene Rubber (Model H120), Part No: 9726-M73

Chrome Plated Machined Brass (Model H131), Part No: 9726-M76

Size Calibrated CUC Series Approx Constant CSt/s Range Centistrokes
25 9721-K50 0.002 0.5 to 2
50 9721-K53 0.004 0.8 to 4
75 9721-K56 0.008 1.6 to 8
100 9721-K59 0.015 3 to 15
150 9721-K62 0.035 7 to 35
200 9721-K65 0.1 20 to 100
300 9721-K68 0.25 50 to 250
350 9721-K71 0.5 100 to 500
400 9721-K74 1.2 240 to 1200
450 9721-K77 2.5 500 to 2500
500 9721-K80 8 1600 to 8000
600 9721-K83 20 4000 to 20000
650 9721-K86 45 9000 to 45000
700 9721-K89 100 20000 to 100000

Ubbelohde Viscometers

Calibrated UBC Series

For measurement of kinetic viscosity of transparent. Newtonian liquids by suspended level principle as described in ASTM D 445 and ISO 3104 and 3105. Similar to Cannon Ubbelohde but less rugged in design.

Provided with certificate of calibration and instruction sheet.

Minimum sample volume 11ML. Require liquid bath of 241mm (9.5 inches).

Holder for above as follows:

Chrome Plated Machine Brass (H130), Part No: 9726/82

Size Calibrated UBC Series Approx Constant CSt/s Range Centistrokes
0 9721-R50 0.001 0.3 to 1
OC 9721-R53 0.003 0.6 to 3
OB 9721-R56 0.005 1 to 5
1 9721-R59 0.01 2 to 10
1C 9721-R62 0.03 6 to 30
1B 9721-R65 0.05 10 to 50
2 9721-R68 0.1 20 to 100
2C 9721-R71 0.3 60 to 300
2B 9721-R74 0.5 100 to 500
3 9721-R77 1 200 to 1000
3C 9721-R80 3 600 to 3000
3B 9721-R83 5 1000 to 5000
4 9721-R86 10 2000 to 10000
4C 9721-R89 30 6000 to 30000
4B 9721-R92 50 10000 to 50000
5 9721-R95 100 20000 to 100000

Reviews

There are no reviews yet, would you like to submit yours?